Banner
Explosion-proof certified infrared temperature sensor

Explosion-proof certified infrared temperature sensor

Product Details

Explosive places need to prevent fire from igniting. Equipment and protection systems that comply with ATEX product regulations or equivalent regulations should be used. The FLIR A310 ex series is an ATEX-certified solution with a thermal imager mounted inside the enclosure that allows it to monitor critical assets and other valuable assets in an explosive environment. Typical applications for the FLIR A310 ex series include process monitoring, quality control and fire detection in explosive locations. Because the FLIR A310 ex series is IP 67 rated, it can be installed in a dusty environment. The "d" class refractory enclosure prevents any explosion accidents inside the enclosure from spreading to the outside of the unit.

Integrated controller

The integrated controller has multiple digital input/output channels and temperature, humidity and pressure sensors. In other functions, the input/output channels allow the user to remotely control the on/off of the camera and heater. Access is achieved through an integrated web interface or Modbus TCP/IP. The integrated controller is equipped with two fibers and two Ethernet ports. This enables flexible network integration within a star or ring topology.

Heater

The FLIR A310 ex series is equipped with a heater to prevent atomization or frosting of the protective window.

Certification ZELM 12 ATEX 0485 X

The FLIR A310 ex series is ATEX certified. It can be installed in the 1, 2, 21 and 22 classification areas. Certification covers the entire system, including the enclosure and all internal components such as thermal imaging cameras, heaters and integrated controllers.


The company sells FLIR thermal imaging cameras, FLUKE thermal imaging cameras , online thermal imaging cameras and other products, welcome to inquire.

Alarm function arbitrarily selected measurement function, digital input, camera temperature and timer have 6 automatic alarm functions

Alarm output digital output, log, save image, file transmission ( ftp), email (SMTP), notification

Detector type focal plane array ( FPA), uncooled microbolometer

Temperature difference calculates the temperature difference between each temperature measurement and the reference temperature

No-load volume 5.06 l

Appearance size [without hood] depth = 170 mm, length = 408 mm

Integrated controller 4-port switch with 2 fiber LC 100Base-FX or 2 RJ45 (10/100) uplinks supporting ring topology for reduced cable laying effort; 2 built-in temperature sensors; air humidity and Pressure sensor; digital output module, controlled by Modbus TCP/IP or web interface to enable on/off heater

Infrared resolution 320 × 240 pixels

Packing size 495 × 370 × 192 mm

Protection class IP67

Protective window , double-sided AR coating, external coating of a hard carbon layer

Set command date /time, temperature °C/°F

Wavelength range 7.5-13μm

Zoom 1–8 times continuous, digital, image interpolation zoom

Content camera (with lens), explosion-proof housing, carton, printed document, user documentation CD-ROM, utility CD-ROM

Housing material and surface plating aluminum / powder coating

Measurement and analysis

 

Accuracy ±2°C or ±2% of reading

Area temperature measurement 10 input boxes with maximum/minimum/average/position

External optical lens and window correction automatically, based on lens /window transmission and temperature input values

1 isotherm , including above and below the isotherm / interval

Measurement correction global and single target parameters

Measurement Options Measurement Mask Filter Call Response: File Send ( ftp), Email (SMTP)

Object temperature range –20 to +120°C 0 to +350°C

Optics transmission correction automatically, based on signals from internal sensors

Reference temperature manual setting, or according to measurement

Reflective apparent temperature correction automatically, based on reflected temperature input value

Point thermometer 10.0

Thermal sensitivity / NETD +30 °C <0.05 °c="" 50="">

Imaging and optics

 

Palette palette (black and white, black and white, iron red, iridescent)

Detector pixel pitch 25μm

Detection time constant is typically 12ms

Aperture number 1.3

Focusing automatically or manually (built-in motor)

Image frequency 30 Hz

Lens recognition automatically

Small focal length 0.4 m

Spatial resolution ( IFOV) 1.36 mrad (25° lens)

Field of View ( FOV) - focal length 25° × 18.8° (18 mm lens)

Storage medium

 

File format standard JPEG, including 16-bit temperature measurement data

power supply

 

Cable length 4 m

Extreme power connection power 60W

Additional heater limit power 16W

Operating voltage 24 V DC

Environmental parameters

 

Working environment temperature range -20 ° C to +40 ° C

Atmospheric transfer correction is automatic, based on input values of distance, atmospheric temperature and relative humidity

Emissivity correction ranging from 0.01 to 1.0

Certification ZELM 12 ATEX 0485 X

Connection and communication

 

Ethernet control, measurement results and images

Ethernet communication based on TCP/IP sockets, FLIR proprietary

Ethernet configuration with fiber optic head with FC connector (fiber)

Ethernet image stream at 7-8 Hz with 16 bits of 320 x 240 pixels - radiation

Ethernet medium multimode branch cable AT-V(ZN)Y(ZN)Y 4G50/125 OM2

Ethernet protocol Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP

Ethernet standard 100 Mbps / IEEE 802.3

Ethernet video stream MPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5

Ethernet cable length 4 m

Storage media built-in image storage memory card

Power cord and configuration German and soft (Helukabel) 37264 flexible cable / fiber optic head

Special explosives protection

 

ATEX certified (certified version - AXC) explosion-proof gas : II 2G Ex d IIC T6 Gb, explosion-proof dust: II 2D Ex tb IIC T85° Db

For explosive areas 1, 2, 21 and 22

Ignition source protection category "d" grade refractory shell

Surface temperature [temperature class T6] The limit temperature is 85 °C


Inquiry